Incinerator Model TS10
Incinerator Model TS10
HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan. Mobile: +86-13813931455(WhatsApp) Website: www.hiclover.com Email: [email protected] Email: [email protected]
Email: [email protected]
Incinerator Model TS10 PLC, Overview
HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification. Auto. Control Waste Incinerator & Auto. Roll Air Filter(Air Purification)
This model Construction is dual/double combustion chamber with 02 units oil burner, batch load incineration equipment. Waste feed chamber is 100Liters (0.1m3, TS10 PLC). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation.
Items/Model
TS10(PLC)
Picture
Burn Rate
Average 10 kg/hour
Feed Capacity
Average 20kg/feeding
Control Mode
Programmable Logic Controller(PLC) Panel
Combustion Chamber
100L
Internal Dimensions
50x50x40cm
Secondary Chamber
50L
Smoke Filter Chamber
Yes
Feed Mode
Manual
Voltage
220V
Power
0.5Kw
Oil Consumption (kg/hour)
average 8.4kg/hour
Gas Consumption (m3/hour)
average 10.1m3/hour
Temperature Monitor
Yes
Temperature Protection
Yes
Oil Tank
100L
Feed Door
30x30cm
Chimney
5 Meter
Chimney Type
Stainless Steel
1st. Chamber Temperature
800℃–1000℃
2nd. Chamber Temperature
1000℃-1200℃
Residency Time
2.0 Sec.
Gross Weight
1500kg
External Dimensions
140x90x120cm